Buyer guide · Choosing fixtures
Lumens per Watt: Comparing LED Fixtures Fairly
Learn how to compare LED fixtures by delivered light and efficacy, not watts alone. A plain guide for contractors, distributors and specifiers.
Request pricing for Linear High BayIn short
Compare the full fixture's published lumens per watt at the selected setting, not bare-chip efficacy or wattage alone. Allmax UHB26 and FLS21 models publish 160 lm/W, while MFD11 flood-light figures vary by wattage and CCT.
On this page
At a glance
| Model | Wattage | Lumens | Efficacy |
|---|---|---|---|
| UHB26-060/080/100CDM-3050L13J · 60 / 80 / 100 W (selectable)LED UFO High Bay Light | 60 / 80 / 100 W (selectable) | 16,000 lm (max) | 160 lm/W |
| UHB26-100/120/150CDM-3050L13J · 100 / 120 / 150 W (selectable)LED UFO High Bay Light | 100 / 120 / 150 W (selectable) | 24,000 lm (max) | 160 lm/W |
| UHB26-100/150/200CDM-3050L13J · 100 / 150 / 200 W (selectable)LED UFO High Bay Light | 100 / 150 / 200 W (selectable) | 32,000 lm (max) | 160 lm/W |
| UHB26-150/200/240CDM-3050L13J · 150 / 200 / 240 W (selectable)LED UFO High Bay Light | 150 / 200 / 240 W (selectable) | 38,400 lm (max) | 160 lm/W |
| MLH06-130W · 130 / 104 / 78 / 52 W (selectable)LED Linear High Bay Light 130–210 W | 130 / 104 / 78 / 52 W (selectable) | 21,200 / 17,500 / 13,500 / 9,300 lm (4000K) | 163 / 168 / 173 / 178 lm/W (4000K) |
| MLH06-165W · 165 / 132 / 99 / 66 W (selectable)LED Linear High Bay Light 130–210 W | 165 / 132 / 99 / 66 W (selectable) | 27,000 / 22,200 / 17,200 / 11,800 lm (4000K) | 163 / 168 / 173 / 178 lm/W (4000K) |
| MLH06-210W · 210 / 180 / 130 / 100 W (selectable)LED Linear High Bay Light 130–210 W | 210 / 180 / 130 / 100 W (selectable) | 34,300 / 30,300 / 22,500 / 17,800 lm (4000K) | 163 / 168 / 173 / 178 lm/W (4000K) |
| MLH06-300W · 300 / 240 / 180 / 120 W (selectable)LED Linear High Bay Light 300 W | 300 / 240 / 180 / 120 W (selectable) | 48,900 / 40,400 / 31,200 / 21,400 lm (4000K) | 163 / 168 / 173 / 178 lm/W (4000K) |
| FLS21-100/120/160U3550L-01CDM · 100 / 120 / 160 W (selectable)LED Linear High Bay Light FLS21 | 100 / 120 / 160 W (selectable) | 25,600 lm (max) | 160 lm/W |
| FLS21-150/200/240U3550L-02CDM · 150 / 200 / 240 W (selectable)LED Linear High Bay Light FLS21 | 150 / 200 / 240 W (selectable) | 38,400 lm (max) | 160 lm/W |
| FLS21-220/260/300U3550L-03CDM · 220 / 260 / 300 W (selectable)LED Linear High Bay Light FLS21 | 220 / 260 / 300 W (selectable) | 48,000 lm (max) | 160 lm/W |
| FLS21-320/360/400U3550L-04CDM · 320 / 360 / 400 W (selectable)LED Linear High Bay Light FLS21 | 320 / 360 / 400 W (selectable) | 64,000 lm (max) | 160 lm/W |
| MFD11-15W · 15 WLED Flood Light 15–65 W | 15 W | 2,100 / 2,250 / 2,150 lm (3000 / 4000 / 5000K) | 140 / 150 / 143 lm/W (3000 / 4000 / 5000K) |
| MFD11-27W · 27 WLED Flood Light 15–65 W | 27 W | 3,800 / 4,050 / 3,900 lm (3000 / 4000 / 5000K) | 141 / 150 / 144 lm/W (3000 / 4000 / 5000K) |
| MFD11-40W · 40 WLED Flood Light 15–65 W | 40 W | 5,700 / 6,000 / 5,800 lm (3000 / 4000 / 5000K) | 143 / 150 / 145 lm/W (3000 / 4000 / 5000K) |
| MFD11-65W · 65 WLED Flood Light 15–65 W | 65 W | 9,200 / 9,700 / 9,400 lm (3000 / 4000 / 5000K) | 142 / 149 / 145 lm/W (3000 / 4000 / 5000K) |
| LED Flood Light 90/120 W 90 W · 90 WLED Flood Light 90/120 W | 90 W | 13,400 / 14,500 / 13,500 lm (3000 / 4000 / 5000K) | 149 / 161 / 150 lm/W (3000 / 4000 / 5000K) |
| LED Flood Light 90/120 W 120 W · 120 WLED Flood Light 90/120 W | 120 W | 17,500 / 19,000 / 18,000 lm (3000 / 4000 / 5000K) | 146 / 158 / 150 lm/W (3000 / 4000 / 5000K) |
Watts tell you power, not light
Watts show how much electricity a fixture draws. They do not show how much useful light comes out. Two fixtures with the same wattage can give very different light levels. When you compare bids, ask for the light output of the full fixture and divide it by the power draw. That gives you a fair number to compare.
Source efficacy and fixture efficacy are different
The Department of Energy explains that two things matter. One is how efficient the LED device itself is. The other is how well the LED and the fixture work together. A fixture also loses some energy in the power supply, and some design features can trade a little efficiency for other benefits. So a strong chip rating does not prove a strong fixture. Ask which number a supplier is quoting.
Optics change how much light reaches the task
A fixture can make plenty of light and still waste some of it. Light that is aimed at the wrong place or trapped in the housing does not help the job. This is why a spec sheet and a photometric file matter. They show where the light goes, not only how much is made. Our spec sheet and IES file guide shows what to request with a submittal.
Efficacy is only one part of the choice
The best number on paper is not always the best fit. Color quality, dimming, expected life and glare all affect how a space works. The Department of Energy notes that higher color quality can involve tradeoffs in cost and efficiency. Match the fixture to the job first. Then use efficacy to choose between the options that fit.
Keep the comparison fair
Compare fixtures that suit the same job, such as one high bay against another high bay. Check that the numbers come from the same kind of rating and the same type of document. Then open the live product page for each fixture to see the exact specifications. Do not rely on a number copied from an old quote or a different model.
Read more
Common questions
Is a higher efficacy number always better?
Not always. It helps you pick between fixtures that already suit the job. Light distribution, color quality, glare and controls still matter.
Which number should I ask a supplier for?
Ask for the light output and power draw of the complete fixture. Ask how the efficacy number was found and whether it covers the whole fixture.
Does efficacy tell me how long a fixture will last?
No. Efficacy is about light for each watt. Life is a separate question, and our lifetime guide explains the common terms.
Where do I find exact specifications for a fixture?
Use the live product page for that fixture. Check it again before you write a final quote or submittal.