Worked answer · High bay calculator

How many high bay lights for a school gym?

Updated

About 4,680 to 5,600 W of LED high bays: for example 14 × 400 W (FLS21) or 35 × 150 W (UHB26). Across every published Allmax high bay setting that is 14 to 92 fixtures for this 8,000 sq ft gym at 50 fc. The assumptions are a 100 × 80 ft floor, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 4,680 to 5,600 W of LED high bays: for example 14 × 400 W (FLS21) or 35 × 150 W (UHB26). Across every published Allmax high bay setting that is 14 to 92 fixtures for this 8,000 sq ft gym at 50 fc. This assumes a 100 × 80 ft floor, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 50 fc is the calculator default for gym.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

8,000 ft² at 50 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm535,300 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm355,250 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm275,400 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm225,280 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm335,280 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm225,280 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm185,400 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm145,600 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm405,200 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm415,330 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm484,992 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm495,096 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm624,836 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm634,914 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm904,680 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm924,784 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm315,115 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm325,280 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm385,016 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm395,148 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm494,851 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm504,950 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm714,686 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm724,752 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm255,250 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm255,250 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm285,040 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm285,040 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm384,940 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm384,940 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm474,700 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm484,800 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm185,400 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm185,400 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm215,040 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm225,280 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm274,860 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm285,040 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm394,680 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm404,800 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide, plus the gymnasium-lighting guide.

Next step

Price a job, or ask for the documents.