Worked answer · High bay calculator

How many high bay lights for a 50,000 sq ft warehouse?

Updated

About 11,682 to 13,230 W of LED high bays: for example 33 × 400 W (FLS21) or 87 × 150 W (UHB26). Across every published Allmax high bay setting that is 33 to 229 fixtures for this 50,000 sq ft open warehouse at 20 fc. The assumptions are a square, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 11,682 to 13,230 W of LED high bays: for example 33 × 400 W (FLS21) or 87 × 150 W (UHB26). Across every published Allmax high bay setting that is 33 to 229 fixtures for this 50,000 sq ft open warehouse at 20 fc. This assumes a square, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 20 fc is the calculator default for open warehouse.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

50,000 ft² at 20 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm13113,100 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm8713,050 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm6613,200 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm5513,200 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm8213,120 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm5513,200 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm4413,200 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm3313,200 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm9912,870 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm10113,130 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm12012,480 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm12212,688 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm15512,090 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm15712,246 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm22511,700 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm22911,908 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm7812,870 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm7913,035 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm9412,408 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm9612,672 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm12212,078 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm12412,276 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm17711,682 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm18011,880 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm6112,810 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm6313,230 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm6912,420 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm7012,600 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm9312,090 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm9512,350 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm11811,800 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm12012,000 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm4312,900 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm4413,200 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm5212,480 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm5312,720 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm6712,060 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm6912,420 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm9811,760 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm10012,000 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide.

Next step

Price a job, or ask for the documents.

IES files and listing file numbers travel with the quotation.