Worked answer · High bay calculator

How many high bay lights for a 30,000 sq ft warehouse?

About 6,996 to 8,100 W of LED high bays: for example 20 × 400 W (FLS21) or 53 × 150 W (UHB26). Across every published Allmax high bay setting that is 20 to 138 fixtures for this 30,000 sq ft open warehouse at 20 fc. The assumptions are a square, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 6,996 to 8,100 W of LED high bays: for example 20 × 400 W (FLS21) or 53 × 150 W (UHB26). Across every published Allmax high bay setting that is 20 to 138 fixtures for this 30,000 sq ft open warehouse at 20 fc. This assumes a square, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 20 fc is the calculator default for open warehouse.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

30,000 ft² at 20 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm797,900 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm537,950 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm408,000 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm337,920 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm497,840 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm337,920 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm278,100 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm208,000 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm597,670 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm617,930 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm727,488 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm737,592 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm937,254 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm947,332 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm1357,020 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm1387,176 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm477,755 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm487,920 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm577,524 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm587,656 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm737,227 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm747,326 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm1066,996 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm1087,128 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm377,770 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm387,980 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm427,560 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm427,560 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm567,280 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm577,410 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm717,100 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm727,200 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm267,800 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm278,100 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm317,440 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm327,680 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm417,380 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm417,380 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm597,080 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm607,200 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide.

Next step

Price a job, or ask for the documents.

IES files and listing file numbers travel with the quotation.