Worked answer · High bay calculator

How many high bay lights for a 15,000 sq ft warehouse?

About 3,498 to 4,200 W of LED high bays: for example 10 × 400 W (FLS21) or 27 × 150 W (UHB26). Across every published Allmax high bay setting that is 10 to 69 fixtures for this 15,000 sq ft open warehouse at 20 fc. The assumptions are a square, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 3,498 to 4,200 W of LED high bays: for example 10 × 400 W (FLS21) or 27 × 150 W (UHB26). Across every published Allmax high bay setting that is 10 to 69 fixtures for this 15,000 sq ft open warehouse at 20 fc. This assumes a square, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 20 fc is the calculator default for open warehouse.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

15,000 ft² at 20 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm404,000 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm274,050 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm204,000 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm174,080 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm254,000 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm174,080 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm144,200 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm104,000 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm303,900 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm314,030 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm363,744 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm373,848 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm473,666 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm473,666 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm683,536 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm693,588 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm243,960 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm243,960 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm293,828 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm293,828 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm373,663 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm373,663 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm533,498 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm543,564 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm193,990 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm193,990 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm213,780 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm213,780 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm283,640 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm293,770 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm363,600 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm363,600 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm133,900 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm144,200 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm163,840 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm163,840 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm213,780 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm213,780 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm303,600 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm303,600 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide.

Next step

Price a job, or ask for the documents.

IES files and listing file numbers travel with the quotation.