Worked answer · High bay calculator

How many high bay lights for a 100,000 sq ft warehouse?

About 23,348 to 26,400 W of LED high bays: for example 66 × 400 W (FLS21) or 174 × 150 W (UHB26). Across every published Allmax high bay setting that is 66 to 458 fixtures for this 100,000 sq ft open warehouse at 20 fc. The assumptions are a square, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 23,348 to 26,400 W of LED high bays: for example 66 × 400 W (FLS21) or 174 × 150 W (UHB26). Across every published Allmax high bay setting that is 66 to 458 fixtures for this 100,000 sq ft open warehouse at 20 fc. This assumes a square, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 20 fc is the calculator default for open warehouse.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

100,000 ft² at 20 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm26126,100 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm17426,100 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm13126,200 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm10926,160 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm16326,080 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm10926,160 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm8726,100 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm6626,400 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm19725,610 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm20126,130 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm23924,856 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm24325,272 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm30924,102 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm31424,492 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm44923,348 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm45823,816 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm15525,575 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm15826,070 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm18824,816 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm19225,344 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm24324,057 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm24724,453 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm35423,364 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm36023,760 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm12225,620 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm12526,250 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm13824,840 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm13925,020 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm18624,180 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm18924,570 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm23523,500 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm23923,900 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm8625,800 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm8726,100 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm10424,960 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm10625,440 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm13424,120 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm13724,660 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm19523,400 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm19923,880 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide.

Next step

Price a job, or ask for the documents.

IES files and listing file numbers travel with the quotation.