Worked answer · High bay calculator

How many high bay lights for a 10,000 sq ft warehouse?

Updated

About 2,340 to 2,800 W of LED high bays: for example 7 × 400 W (FLS21) or 18 × 150 W (UHB26). Across every published Allmax high bay setting that is 7 to 46 fixtures for this 10,000 sq ft open warehouse at 20 fc. The assumptions are a square, 25 ft mounting height, CU 0.60 and LLF 0.80.

Direct answer

About 2,340 to 2,800 W of LED high bays: for example 7 × 400 W (FLS21) or 18 × 150 W (UHB26). Across every published Allmax high bay setting that is 7 to 46 fixtures for this 10,000 sq ft open warehouse at 20 fc. This assumes a square, a 25 ft mounting height, coefficient of utilization (CU) 0.60 and light-loss factor (LLF) 0.80. The target of 20 fc is the calculator default for open warehouse.

Fixture height is recorded for the layout request. It does not change this average lumen calculation because height, optics, obstructions and task planes require photometric data.

Fixture count by published model and setting

10,000 ft² at 20 fc, CU 0.60 and LLF 0.80
Allmax model and settingWattsPublished lumensFixture countTotal watts
UHB26-060/080/100CDM-3050L13J · 16,000 lm
Published maximum
100 W16,000 lm272,700 W
UHB26-100/120/150CDM-3050L13J · 24,000 lm
Published maximum
150 W24,000 lm182,700 W
UHB26-100/150/200CDM-3050L13J · 32,000 lm
Published maximum
200 W32,000 lm142,800 W
UHB26-150/200/240CDM-3050L13J · 38,400 lm
Published maximum
240 W38,400 lm112,640 W
FLS21-100/120/160U3550L-01CDM · 25,600 lm
Published maximum
160 W25,600 lm172,720 W
FLS21-150/200/240U3550L-02CDM · 38,400 lm
Published maximum
240 W38,400 lm112,640 W
FLS21-220/260/300U3550L-03CDM · 48,000 lm
Published maximum
300 W48,000 lm92,700 W
FLS21-320/360/400U3550L-04CDM · 64,000 lm
Published maximum
400 W64,000 lm72,800 W
MLH06-130W · 21,200 lm
4000 K
130 W21,200 lm202,600 W
MLH06-130W · 20,800 lm
5000 K
130 W20,800 lm212,730 W
MLH06-130W · 17,500 lm
4000 K
104 W17,500 lm242,496 W
MLH06-130W · 17,200 lm
5000 K
104 W17,200 lm252,600 W
MLH06-130W · 13,500 lm
4000 K
78 W13,500 lm312,418 W
MLH06-130W · 13,300 lm
5000 K
78 W13,300 lm322,496 W
MLH06-130W · 9,300 lm
4000 K
52 W9,300 lm452,340 W
MLH06-130W · 9,100 lm
5000 K
52 W9,100 lm462,392 W
MLH06-165W · 27,000 lm
4000 K
165 W27,000 lm162,640 W
MLH06-165W · 26,400 lm
5000 K
165 W26,400 lm162,640 W
MLH06-165W · 22,200 lm
4000 K
132 W22,200 lm192,508 W
MLH06-165W · 21,800 lm
5000 K
132 W21,800 lm202,640 W
MLH06-165W · 17,200 lm
4000 K
99 W17,200 lm252,475 W
MLH06-165W · 16,900 lm
5000 K
99 W16,900 lm252,475 W
MLH06-165W · 11,800 lm
4000 K
66 W11,800 lm362,376 W
MLH06-165W · 11,600 lm
5000 K
66 W11,600 lm362,376 W
MLH06-210W · 34,300 lm
4000 K
210 W34,300 lm132,730 W
MLH06-210W · 33,600 lm
5000 K
210 W33,600 lm132,730 W
MLH06-210W · 30,300 lm
4000 K
180 W30,300 lm142,520 W
MLH06-210W · 30,000 lm
5000 K
180 W30,000 lm142,520 W
MLH06-210W · 22,500 lm
4000 K
130 W22,500 lm192,470 W
MLH06-210W · 22,100 lm
5000 K
130 W22,100 lm192,470 W
MLH06-210W · 17,800 lm
4000 K
100 W17,800 lm242,400 W
MLH06-210W · 17,500 lm
5000 K
100 W17,500 lm242,400 W
MLH06-300W · 48,900 lm
4000 K
300 W48,900 lm92,700 W
MLH06-300W · 48,000 lm
5000 K
300 W48,000 lm92,700 W
MLH06-300W · 40,400 lm
4000 K
240 W40,400 lm112,640 W
MLH06-300W · 39,600 lm
5000 K
240 W39,600 lm112,640 W
MLH06-300W · 31,200 lm
4000 K
180 W31,200 lm142,520 W
MLH06-300W · 30,600 lm
5000 K
180 W30,600 lm142,520 W
MLH06-300W · 21,400 lm
4000 K
120 W21,400 lm202,400 W
MLH06-300W · 21,000 lm
5000 K
120 W21,000 lm202,400 W

Counts are rounded up. UHB26 and FLS21 use published maximum output at maximum wattage. MLH06 rows keep each published wattage and color-temperature output together.

Use this count as a planning estimate

Planning estimate, not a photometric layout. Racks, court equipment, room surfaces, optics, glare and required uniformity can change the layout and final quantity.

Request a photometric layout or change the inputs in the high bay calculator.

Read the warehouse lighting lumen-method guide, linear high bay versus UFO guide and high bay mounting-height guide.

Next step

Price a job, or ask for the documents.

IES files and listing file numbers travel with the quotation.

Request a quote