Buyer guide · Choosing fixtures

Commercial Lighting CCT and CRI: Choosing Color

Choose commercial LED color temperature and CRI separately from light output, using task requirements, sample reviews and model-specific Allmax data.

Request pricing for 4-inch LED Commercial Downlight A-DL13

In short

Choose CCT for light appearance and CRI for color rendering, then check lumens separately on the exact row. MFP01 publishes 3500/4000/5000K with CRI above 80, while wraparound models publish CRI 80 or 90 with different outputs at the same wattage.

On this page
  1. At a glance
  2. Separate light appearance, color rendering and output
  3. Choose color temperature in the actual room
  4. Use CRI as one part of a task-specific requirement
  5. Compare the published Allmax configurations separately
  6. Carry the color decision into ordering and maintenance
  7. Common questions
  8. Related guides

At a glance

Published CCT and CRI by model
ModelWattageCCTCRILumens (by wattage)
MFP01-22F-40W · 40 / 30 / 20 W (selectable)LED Flat Panel Light40 / 30 / 20 W (selectable)3500 / 4000 / 5000K (selectable)> 804,700 / 3,600 / 2,500 lm
MFP01-14F-40W · 40 / 30 / 20 W (selectable)LED Flat Panel Light40 / 30 / 20 W (selectable)3500 / 4000 / 5000K (selectable)> 804,700 / 3,600 / 2,500 lm
MFP01-24F-50W · 50 / 40 / 30 W (selectable)LED Flat Panel Light50 / 40 / 30 W (selectable)3500 / 4000 / 5000K (selectable)> 806,100 / 4,900 / 3,800 lm
TRF14-TCP40W-CCT · 40 / 30 / 25 / 20 / 15 W (selectable)LED Troffer Light TRF40 / 30 / 25 / 20 / 15 W (selectable)3500 / 4000 / 5000 / 5700 / 6500K (selectable)Ra > 806,179 lm (max)
TRF22-TCP40W-CCT · 40 / 30 / 25 / 20 / 15 W (selectable)LED Troffer Light TRF40 / 30 / 25 / 20 / 15 W (selectable)3500 / 4000 / 5000 / 5700 / 6500K (selectable)Ra > 806,142 lm (max)
TRF24-TCP50W-CCT · 50 / 40 / 35 / 30 / 25 W (selectable)LED Troffer Light TRF50 / 40 / 35 / 30 / 25 W (selectable)3500 / 4000 / 5000 / 5700 / 6500K (selectable)Ra > 806,182 lm (max)
Z-FLWR2R80 · 20 WLED Wraparound Light20 W5 selectable CCTs802,000 lm
Z-FLWR2R90 · 20 WLED Wraparound Light20 W5 selectable CCTs901,700 lm
Z-FLWR4R80 · 40 WLED Wraparound Light40 W5 selectable CCTs804,000 lm
Z-FLWR4R90 · 40 WLED Wraparound Light40 W5 selectable CCTs903,400 lm
A-DL13-D4-UNV-CCT-R90-WS · 13 / 10 / 7 W (selectable)4-inch LED Commercial Downlight A-DL1313 / 10 / 7 W (selectable)2700 / 3000 / 3500 / 4000 / 5000K (selectable)90645 – 1,325 lm
A-DL22-D6-UNV-CCT-R90-WS · 22 / 18 / 16 / 14 / 12 W (selectable)6-inch LED Commercial Downlight A-DL2222 / 18 / 16 / 14 / 12 W (selectable)2700 / 3000 / 3500 / 4000 / 5000K (selectable)901,110 – 2,040 lm

Separate light appearance, color rendering and output

A request for brighter, whiter light can conceal several different problems. The room may have insufficient light at the task, an unwanted color appearance, or difficulty distinguishing materials. Ask which problem the user sees before changing the fixture specification.

Correlated color temperature, or CCT, describes the appearance of white light and is expressed in kelvin. Lower values generally appear warmer; higher values generally appear cooler. Color rendering describes how a light source affects the appearance of objects. CRI is one measure of that rendering, commonly reported as Ra.

DOE's color-characteristics fact sheet explains why CCT and color rendering describe different properties. Neither is a substitute for lumen output or illuminance at the work surface. A cooler setting does not, by itself, establish that a desk or rack receives more light.

At the distributor counter, translate the request into separate fields: intended task, preferred CCT, required color-rendering evidence and required output. Keep those fields separate in the fixture schedule so a substitution does not accidentally change one while matching another.

Choose color temperature in the actual room

Questions to resolve before choosing CCT
Project conditionUseful reviewRecord
Partial replacementCompare new and retained lighting togetherApproved setting for each area
Office or classroomReview finishes, screens and daylightSample location and user feedback
Material inspectionEvaluate representative samplesTask-specific rendering requirement
Circulation and support roomsCheck transitions between spacesConsistent room schedule
Outdoor installationReview project and local requirementsSpecified CCT and approved fixture

Use these as review steps, not mandatory temperature prescriptions. A building type does not determine one correct CCT. The owner, designer and users should agree on the desired result in the actual environment.

For a sample review, place representative finishes and materials under the proposed light. Compare settings at similar illumination, rather than selecting whichever sample happens to be brighter. Include adjacent retained fixtures and daylight where they will normally be present.

Record the selected setting by room or fixture tag. A verbal instruction such as neutral white is less useful than an agreed numerical setting supported by the approved product data. Keep the sample decision with the submittal so later replacements follow it.

Use CRI as one part of a task-specific requirement

CRI compares the appearance of test colors under a source with a reference. An average score cannot describe every color shift. Two sources with a similar CRI may therefore produce different results on the particular materials a project needs to evaluate.

For routine circulation, the project may use a simple documented CRI requirement. For color matching or inspection, tell the specifying engineer what objects must be distinguished. Provide samples of those objects when possible. Do not treat a higher average number as proof that every visual task improves.

The IES discussion of color specification explains how TM-30 adds information about fidelity and changes in color saturation. A designer can decide whether additional color data are necessary. Ask whether those data exist for the proposed configuration before making them a product-selection assumption.

Maintain a clear distinction between evidence and preference. A sample can help users agree on appearance; a measured report supports a performance requirement. If a product page leaves CRI blank, record that as a documentation gap. Do not fill it with a value from another size or visually similar fixture.

Compare the published Allmax configurations separately

The wraparound model table shows why CRI and output should remain separate. The Z-FLWR2R80 row publishes CRI 80 and 2,000 lm; Z-FLWR2R90 publishes CRI 90 and 1,700 lm. Both publish 20 W. These are documented variants, not a universal rule about every change in CRI.

The MFP01 flat-panel table publishes CRI greater than 80 and selectable 3500 / 4000 / 5000 K. The TRF troffer table publishes Ra greater than 80, with its own five CCT settings. Do not transfer one family's available settings to another.

The 4-inch A-DL13 downlight and 6-inch A-DL22 downlight publish five CCT settings from 2700 to 5000 K and CRI 90. That CRI belongs to these two models; do not carry it over to another family that publishes a lower value.

The wraparound table uses the label "5 selectable CCTs" without enumerating its temperatures. Preserve that distinction when preparing an order. A count of settings does not identify their values or prove a match to an adjacent fixture.

Carry the color decision into ordering and maintenance

A sample decision can be lost when the order lists only a family name. Include the exact model and the selected CCT in the fixture schedule. Where a family offers CRI variants, identify the intended variant explicitly. Record the corresponding lumen output rather than mixing values from different rows.

  • State the room, visual task and any retained lighting that must be considered.
  • List the selected CCT and the project's color-rendering requirement separately.
  • Attach the model-specific product data and any requested color measurements.
  • Record sample-review decisions, including materials and viewing conditions.
  • Give maintenance staff the approved setting and replacement model information.

Field-selectable CCT should follow the installation instructions and an agreed schedule. Do not leave each installer to choose a setting independently. During handover, check rooms from normal viewing positions and investigate mismatched appearance before treating the project as complete.

Distributors can use RFQ to submit a fixture schedule with the required color fields. Specifying engineers should identify any measurement beyond the published data and explain the task it supports. That makes the remaining evidence request specific and reviewable.

Common questions

Is 5000 K brighter than 3500 K?

CCT alone does not answer that. Compare documented output and the light delivered to the task at the selected configuration.

Does CRI 90 guarantee accurate color matching?

No single average score establishes every color-matching result. Define the task and ask the designer whether additional measurements or a sample review are needed.

Does selectable CCT mean the fixture changes color automatically?

No. A selectable setting does not establish a scheduled or continuously tunable control function. Confirm the documented adjustment method and controls.

Can two fixtures with the same CCT look different?

Yes. CCT does not describe every aspect of color appearance or rendering. Compare the exact products in the proposed setting when appearance matching matters.

Next step